Analogue Insulation Tester

 

MODEL 3165/3166
 
Selection Guide
 

500V/1000MΩ(Model 3165)
1000V/2000MΩ (Model 3166)
Expanded megohm scale for easy reading.
New robust housing case to prevent damage.
AC voltmeter scale for easy reading.
Neck strap for both hand’s operation.
3165/3166
 
MODEL 3165 3166
Insulation Resistance
DC Test Voltage 500V 1000V
Max. Effective
Scale Value
1000MΩ 2000MΩ
Mid-Scale Value 20MΩ 50MΩ
First Effective
Measuring Range
Accuracy
1 - 500MΩ 2 - 1000MΩ
|±5% rdg
Second Effective
Measuring Range
Accuracy
0.5/1000MΩ 1/2000MΩ
|±10% rdg
AC Voltage 600V
Accuracy |±3% of full scale value
Withstand Voltage 3700V AC for 1 minute
Power Source R6 (AA) (1.5V) × 4
Dimensions 90(L) × 137(W) × 40(D)mm
Weight 330g approx.
Accessories 7025 (Test leads)
9067 (Pouch for test lead)
Neck Strap
R6 (AA) × 4
Instruction Manual

 

Analogue Insulation / Continuity Tester

 

MODEL 3132A
 
Selection Guide Product Catalogue
 

Dust and drip proof construction. (designed to IEC 60529 IP54)
Designed to meet IEC 61010-1 and IEC 61557 safety standard.
1mA rated test current at the minimum resistance.
200mA measuring current on continuity testing.
Automatic discharge of circuit capacitance.
(Any charge stored in the circuit under test will be automatically discharged after testing.)
Live circuit warning buzzer and neon lamp.
Small and lightweight. Shock resistant new case material.
AC voltmeter with linear, easy-to-read scale.
Operates on AA, R6 × 6 dry batteries.

3132A
CE
 
Insulation Resistance
Test Voltage 250V/500V/1000V
Measuring Ranges 
(Mid-scale Value)
100MΩ/200MΩ/400MΩ 
(1MΩ) (2MΩ) (4MΩ)
Output Voltage 
on open circuit
Rated test voltage+20%, -0%
Nominal Current 1mA DC min.
Output Short
Circuit Current
1 - 2mA DC
Accuracy 0.1 - 10MΩ/0.2 - 20MΩ/0.4 - 40MΩ
(Accuracy Guaranteed Ranges) ±5% of indicated value
Continuity
Measuring Ranges 
(Mid-scale Value)
3Ω/500Ω
(1.5Ω) / (20Ω)
Output Voltage 
on open circuit
4.1V DC approx.
Measuring Current 210mA DC min.
Accuracy |±1.5% of scale length
AC Voltage
AC Voltage 0 - 600V AC
Accuracy |±5% of scale length
General
Safety Standard IEC 61010-1 CAT III 600V Pollution Degree 2
IEC 61010-2-031
IEC 61557-1/2/4
IP Rating IEC 60529-IP54
EMC Standard IEC 61326-1
Withstand Voltage 3700V AC for 1 minute
Power Source R6 (AA) (1.5V) × 6
Dimensions 106(L) × 160(W) × 72(D)mm
Weight 560g approx.
Accessories 7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 6 
Shoulder Strap 
Instruction Manual

 

High Voltage Insulation Tester

 

KEW 3128
 

High Voltage Insulation Tester
Selection Guide Product Catalogue
Software Instruction Manual
 

Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions.
Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc.
6 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 12000V
Fine adjustment of voltage setting at each range is also possible
Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight.
Can be operated from built-in rechargeable battery or from AC line.
Automatic discharge after test with monitoring of the discharge voltage.
Internal memory can store about 43,000 data (max).
Robust design for field use with IP64 rating (with lid closed).

3128
CEAUTO DISCHARGE

Backlight USB  
  3128 500V/1000V/2500V/5000V/10000V/12000V
Insulation resistance (*): Accuracy is not guaranteed with setting of 250V or less
Rated voltage 500V 1000V 2500V 5000V 10000V 12000V
Max
measurement
value
500GΩ 1TΩ 2.5TΩ 5TΩ 35TΩ
Accuracy 400k - 50GΩ
±5%rdg±3dgt
(*)
800k - 100GΩ
±5%rdg±3dgt
2M - 250GΩ
±5%rdg±3dgt
4M - 500GΩ
±5%rdg±3dgt
8M - 1TΩ
±5%rdg±3dgt
50G - 500GΩ
±20%rdg
(*)
100G - 1TΩ
±20%rdg
250G - 2.5TΩ
±20%rdg
500G - 5TΩ
±20%rdg
1T - 10TΩ
±20%rdg
10T - 35TΩ
Values are displayed, but accuracy isn't guaranteed
Short circuit current Max 5.0mA
Load resistor to output rated voltage 0.5MΩ or more 1MΩ or more 2.5MΩ or more 5MΩ or more 20MΩ or more 24MΩ or more
Output voltage
Rated voltage 500V 1000V 2500V 5000V 10000V 12000V
Monitor accuracy ±10%±20V ±10%±20V ±10%±20V ±10%±20V ±10%±20V ±10%±20V
Output accuracy 0 - +20% 0 - +10% 0 - +10% 0 - +10% -5 - +5% -5 - +5%
Selectable range 50 - 600V
(in steps of 5V)
610 - 1200V
(in steps of 10V)
1225 - 3000V
(in steps of 25V)
3050 - 6000V
(in steps of 50V)
6100 - 
10000V
(in steps of 100V)
10100 - 
12000V
(in steps of 100V)
Voltage measurement
Measuring range DCV : ±30 - ±600V, ACV : 30 - 600V (50/60Hz)
Accuracy ±2%rdg±3dgt
Current measurement
Measuring range 5.00nA - 2.40mA (Depending on the insulation resistance)
Capacitance measurement
Measuring range 5.0nF - 50.0µF 5.0nF - 1.0µF
(display range: 5.0nF - 50.0µF)
Accuracy ±5%rdg±5dgt
General
Withstand voltage AC8770V : between line terminal and enclosure / 5sec (50/60Hz)
AC6880V : between the measuring terminal and enclosure / 5sec (50/60Hz)
AC2330V : between the power connector and enclosure / 5sec (50/60Hz)
Operating temperature & humidity range
-10ºC - 50ºC / Relative humidity 85% or less
(when operating with an external power supply, no condensation)
0ºC - 40ºC / Relative humidity 85% or less
(when operating with battery, no condensation)
Storage temperature & humidity range -20ºC - 60ºC / Relative humidity 75% or less (no condensation)
Applicable standards IEC 61010-1 CAT IV 600V Pollution degree 2,
IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed.
Power source Rechargeable Lead storage battery (12V)*
Charging time: approx. 8 hours / AC Power supply (100V - 240V, 50/60Hz)

* Continuous measuring time:
approx. 4 hours
(a load of 100MΩ at the Insulation resistance 12000V Range.)
approx. 2 hours
(Max current consumption in range while rated currents are maintained.)
Dimension 330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case
Weight 9kg approx. (including battery) *Instrument and Hard case
Accessories 7170 (Main cord), 7224A (Earth cord), 7225A (Guard cord), 7226A (Line probe),
7227A (Line probe with alligator clip), 8029 (Extension prod),
8212-USB-W (USB adaptor with KEW Windows (Software)),
Instruction manual
Optional 7254 (Longer Line probe with alligator clip)

 

Analogue Insulation / Continuity Tester

 

MODEL 3131A
 
Selection Guide Product Catalogue
 

The Model 3131A offers unmatched performance, and feature including test lead resistance zero adjustment for time-saving continuous operation, a clear ease to read illuminated scale, and a live circuit warning.
Test insulation up to 100MΩ at 250V, 200MΩ at 500V, 400MΩ at 1000V and continuity up to 20Ω.
LIVE circuit warning lamp plus audible warning.
Automatic discharge of circuit capacitance when TEST button is released.
Fuse protected (continuity range only).
Battery check LED.
Front panel zero adjust.
Back light function to facilitate working at dimly lit situations.
PRESS TO TEST button with lock down feature.
3131A
CE
 
Insulation Resistance
Test Voltage 250V/500V/1000V
Measuring Ranges 
(Mid-scale Value)
100MΩ/200MΩ/400MΩ
(1MΩ) (2MΩ) (4MΩ)
Output Voltage
on open circuit
Rated test voltage+20%, -0%
Nominal Current 1mA DC min.
Output Short
Circuit Current
1.3 mA DC approx.
Accuracy 0.1 - 10MΩ/0.2 - 20MΩ/0.4 - 40MΩ
(Accuracy Guaranteed Ranges) ±5% of indicated value
Continuity
Measuring Ranges
(Mid-scale Value)
2Ω/20Ω
(1Ω) (10Ω)
Output Voltage
on open circuit
4 - 9V DC
Measuring Current 200mA DC min.
Accuracy |±3% of scale length
General
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031
IEC 61557-1/2/4
IP Rating IEC 60529-IP54
EMC Standard IEC 61326-1
Withstand Voltage 3700V AC for 1 minute
Power Source R6 (AA) (1.5V) × 6
Dimensions 167(L) × 185(W) × 89(D)mm
Weight 860g approx.
Accessories 7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 6
Shoulder Strap
Instruction Manual

 

     

 

STORE

  • Plaza Kenari Mas , Lt. LG Blok B121 , Jalan Kramat Raya No. 101 , Paseban, Senen , JakPus 10440 , Phone : (021)-29478925

  • LTC Glodok Lt. 2 Blok C3 No. 3-5 , Jl. Hayam Wuruk No.127, Mangga Besar, Tamansari, Kota, Jakarta Barat 11180 , Phone : (021)22685705

OFFICE

Ruko Concordia SRB 26, Kota Wisata Cibubur Bogor 16968 Indonesia

Phone : (0 21)-29478974  

Mobile/WA : 0811 1388 063

 Email : sales@ptbestinstrument.com